Home

   BiolinkArg • Argentina    

   Biolink / Andover • Chile

   Biolink • América do Sul

 

 

 

 

 

QUEM SOMOS

 

 

 

 

 

 

FALE CONOSCO  

 

 

 Formulário de Contato

 + 55 11 3662-0762

 + 55 11 3825-7311

 biolink@biolink.com.br

 

 

 

 

 

 

CONTATO ON LINE

 

 

 

 

 

 

NEUROSCAN

 

 

Softwares, Amplificadores
e Acessórios para Pesquisa
em Neurociência

 

 

Access SDK

 

 

Curry 6

 

 

Maglink

 

 

Neuvo EEG LTM

 

 

Quik-Caps

 

 

QuikCell

 

 

Scan

 

 

Scan Nuamps Express

 

 

Source 5

 

 

Source 2

 

 

Stim2

 

 

SynAmps RT

 

 

 

 

 

 

MEDOC

 

 

Sistemas de Neuro Diagnóstico para Pesquisa
da Dor Cônica e Aguda

 

 

Algomed

 

 

Covas

 

 

Pathway

 

 

Pathway Model ATS

 

 

Pathway Model ATS
Accessories

 

 

Pathway Model Cheps

 

 

Pathway Model Cheps Accessories

 

 

TSA II Neuro Sensory
Analyzer

 

 

TSA II
Accessories

 

 

VSA-3000 - Vibratory
Sensory Analyzer

 

 

 

 

 

 

   CAREFUSION

 

 

Equipamentos para
Neurodiagnóstico:
EEG, EMG, PE e IOM

 

 

Endeavor CR IOM

 

 

Synergy N2 - EMG

 

 

Synergy T2 - EMG

 

 

Synergy N-EP - EMG/PE

 

 

Synergy T-EP - EMG/PE

 

 

NicoletOne

 

 

 

Ambulatory EEG

 

 

 

cEEG

 

 

 

nEEG

 

 

 

LTM

 

 

 

Sleep

 

 

 

vEEG

 

 

Nicolet Monitor
UTI Neurológica

 

 

VikingQuest IOM

 

 

VikingQuest EMG

 

 

 

 

 

 

ALPHA OMEGA

 

 

Equipamentos para Pesquisa
Biomédica em Animais

 

 

Gravação e Estimulação
In Vivo

 

 

 

AlphaLab SnR

 

 

 

TeleSpike

 

 

 

TeleSpike Mini

 

 

Micromanipuladores

 

 

 

EPS

 

 

 

FlexMT

 

 

 

MultiDrive

 

 

Matriz de Microeletrodos
In Vitro

 

 

 

Microeletrodos In Vitro

 

 

Acessórios Neurociências

 

 

 

Eletrodos

 

 

 

MEA - Matriz de Microeletrodo

 

 

 

FMA - Matriz de Microeletrodo Flutuante

 

 

 

LMA - Matriz de Microeletrodo Linear

 

 

 

MWA - Matriz Microwire

 

 

 

Eletrodo Injetor

 

 

 

 

 

 

UGO BASILE

 

 

Instrumentação para
Pesquisa em Animais
de Laboratório

 

 

Dor e Inflamação

 

 

Coordenação Motora, Atividade e Força de Preensão

 

 

Ventilação e Gases Anestésicos

 

 

Condicionamento e Recompensa

 

 

Labirintos e
Monitoramento

 

 

Banho de Órgãos, Gravação e
Estimuladores

 

 

ECT, Produtor de
Lesões, Diversos

 

 

Pressão Sanguínea e Funções Vitais

 

 

Metabolismo e Comportamento
Alimentar

 

 

Fixação por Irradiação
de Microondas

 

 

 

 

 

 

AEROCRINE

 

 

Medidor Portátil de Fração Exalada de Óxido Nítrico (FeNO)

 

 

Niox Mino
Analisador FeNO

 

 

 

Asma

 

 

 

Óxido Nítrico

 

 

 

O NO e a Inflamação

 

 

 

 

 

 

DIGITIMER

 

 

Estimuladores Elétricos e Geradores de Pulso para Pesquisa

 

 

Estimulador Cortical
Digitimer D185

 

 

 

 

 

 

EDAN

 

 

Ultra-Som Veterinário

 

 

Dus 6 Vet

 

 

 

 

 

 

SENSOR DE OXIMETRIA

 

 

Sensores de Oximetria
Compatíveis com Várias
Marcas de Oximetros

 

 

Clip de Dedo

 

 

Clip de Orelha

 

 

Soft Silicone

 

 

Flexi-Site Y Infantil

 

 

 

 

 

 

PASTA PARA EEG

 

 

Pastas e Géis para Preparação da Pele e Condução para Eletrodos

 

,

Pasta Abrasiva
Escarificante

 

 

Pasta Condutiva

 

 

Pasta Condutiva e Adesiva

 

 

Gel Condutivo

 

 

 

 

 

 

POLISSONOGRAFIA

 

 

Conserto e Reforma
de Sensores para
Polissonografia

 

       
   
 
NeuroScan  |  MagLink  |  Scan NuAmps Express  |  SynAmps RT  |  Stim2  |  Curry 6  |
Source 2  |  Source 5  |  Scan 4.5  |  Access SDK  |  Quik-Caps  |  Quik-Cell |  Neuvo EEG LTM  |
 
 
 

SynAmps RT

  SynAmps RT  
   

Usando as duas últimas décadas de experiência e a melhor tecnologia disponível, a Neuroscan tem o prazer de oferecer à comunidade neurocientífica o SynAmps RT. Dedicada às gravações de alta densidade, em um sistema de amplificação de 70 canais, com 64 monopolares e 4 ou 2 canais de alto nível. Cada canal têm um conversor AD de 24 bits, para garantir uma amostragem mais precisa.

 
         
         
 



  Active Noise Cancellation is an integral feature of the SynAmps RT design, providing unparalleled noise immunity. This ensures an accurate representation of the neurophysiological activity even in the most hostile electromagnetic environments.  
       
    Using the latest technology has not only allowed us to make the SynAmps RT our most capable amplifier ever, it has also allowed us to put it into a small, cost effective package.  
       
    SynAmps RT Consists of Three Components:  
       
    Headbox - Each Headbox consists of 70 channels, and multiple Headboxes can be linked together to build high-density systems. Our modular approach to amplifiers provides a simple and flexible upgrade path.  
       
    All of the essential electronics have been moved to the Headbox. Our low noise 24 bit A-to-D chip allows for low gain to be used while still maintaining the resolution required for the most critical researcher. Data is digitized immediately in the headbox and transmitted to the host computer via a high-speed USB-2 connection guaranteeing lossless transmission. Quality of the signal is assured by our impedance testing circuitry, which allows you to verify impedance both on the Headbox and in a software display.  
       
    Touch-proof connectors are provided to allow for the greatest flexibility, while our high-density connector permits Quik-CapTM to be easily connected. Inputs for high-level signals are also provided, allowing you to capture the time series data of other measures along with the EEG.  
       
    System Unit - Serving as a hub for multiple Headboxes, the system unit is the distribution center, assuring absolute synchronization of sampling and triggers between all of the Headboxes. The System Unit is also the communication center with the host computer. Using a USB2 connection, the system unit ensures accurate transmission of data and trigger timing information.  
       
    Power Unit - Isolation of the subject from the power mains is a critical safety aspect of a complete system. The Power Unit houses a medical grade transformer, allowing you to connect those devices that contact the subject to one reference point. This assures that leakage currents and proper grounding meet world wide certification safety requirements for patient connected devices.  
       
    SynAmps RT Highlights  
       
    Design Features   
       
    Headbox-Based Amplification - Analog signals, whether buffered or not, are susceptible to noise. With the SynAmps RT, signals are amplified and digitized right at the patient side, providing a digital signal transmission path and providing the very best signal integrity.   
       
    70 Channel Headbox Units - Allows you to use ALL of your channels. The SynAmps RT offers two external auxiliary and four bipolar inputs in addition to the standard 64 channels per headbox. You don't have to convert bipolar channels to monopolar to get your full montage.   
       
    Check Electrode Impedances Right at the Headbox - Electrode impedances are checked against a user-selectable threshold and the results are instantly available at the headbox.   
       
    Compact System Design - Each system consists of one or more headboxes, weighing in at less than 5 lbs, a system unit and a power unit. System and power units will handle multiple headboxes for high-density recordings.   
       
    Up to 256 EEG Channels on a Single Small System Unit - A single system unit will handle up to four head boxes, creating a 256 channel system in about one quarter the space of the original SynAmps unit. Combine two system units to create a super-high density system.   
       
    Standard Windows Computer and USB 2.0 Interface - Plug and play operation makes connection and setup easy and fast. No proprietary analog to digital, PCI or data interface cards need to be installed, complicating the system. The industry standard USB 2.0 interface will allow you to move to another PC easily.   
       
    Quik-Caps from Neuromedical Supplies Connect Directly - Conversion (EBA) cables are no longer required for cap connection. Neuromedical Supplies Quik-Caps connect directly to the quick-disconnect high-density connector on each headbox for no-problem patient setup. Touch Proof connections for each channel are also provided.  
       
    Technical Features   
       
    24-Bit Data Conversion - Even within all the excellent high-bit count analog to digital (A/D) converters currently on the market, we"ve specially selected the quietest product available for use in the new SynAmps RT, delivering the best signals with the greatest dynamic range possible. You demand clean, high-resolution data and we deliver it. Data from the SynAmps RT also flows seamlessly through to the new 32-bit version of Scan.  
       
    Active Noise Cancellation - Provides unparallel noise immunity. This ensures an accurate representation of the neurophysiological activity even in the most hostile electromagnetic environments   
       
    1 G Ohm Input Impedance - The very best in instrumentation amplifier technology is used to ensure that your signals are faithfully recorded.   
       
    External (auxiliary) Sensors can be Connected With Ease - Two external inputs per headbox come standard. Both are isolated from patient and computer connections with a+/-5 volt input range. Data is time locked with the EEG data.  
       
    External (auxiliary) Sensors Require No External Power - Sensors can be powered from the headbox. up to +/-10V at 100mA. This enables use of strain gauges and a wide range of input devices where the output is time locked to the acquired data.  
       
    Bandwidth/Acquisition Rates for the Studies You Want to Run - You want the capability to go from GSR to ABR in one instrument. If you need extra bandwidth and higher acquisition rates, SynAmps RT should be your device of choice. With SynAmps RT, you will never wonder if part of the signal you needed for source or other analysis is above the bandwidth of your data collection device.  
       
    Advanced Impedance Technology - Enables the use of advanced impedance modeling techniques and allows you to obtain impedance of the reference electrode in addition to the typical recording channels.  
       
    System Integration Features  
       
    Built-In Compatibility With Other Neuroscan Products - The seamless system integration that you've come to expect from Neuroscan continues with SynAmps RT. A totally integrated system including amplifier, data acquisition, stimulus generation, data analysis, and source analysis means that you spend your time doing research, not putting systems together.  
       
    Backwards Compatibility With Your Existing STIM or Other Stimulus Generation Programs - SynAmps RT uses the same trigger connector that the original SynAmps and NuAmps use, so there is no need to modify your existing stimulus protocols.  
       
    MagLink Compatibility - SynAmps RT was designed with the difficulties of recording in the MRI in mind. Specific engineering considerations were built in to the system to provide the best possible recordings in the MRI.  
       
    Advanced De-blocking Circuitry - Allows for recording of TMS and other high intensity stimuli, maximizing the data integrity without affecting the amplifier.  
       
    Extended Cabling Systems - Allows your headbox to be positioned up to 10m away from the system unit for maximum flexibility. Cabling and filters for shielded room patch panels will also be available.  
       
    Head box Mounting Options - Multiple mounting options, including wall, tripod and table mount, ensure that head box can be secured in your recording environment.  
       
    Integrated Power Supply - In addition to powering the SynAmps RT, the power unit will allow you to power up to 4 additional devices, ensuring a common ground is used in all of your patient connected equipment.  
       
    Specifications:  
       
    •Monopolar Channel Count......64 Per Headbox, 256 Per System Unit
•Bipolar Channel Count...........4 Per Headbox, 16 Per System Unit
•High Level Channel Count.....2 Per Headbox, 8 Per System Unit
•Maximum Sampling Rate.......20,000 Hz / Channel all channels driven
•Sampling Method..................All Channels Sampled Simultaneous
•A/D Resolution.....................24 Bit
•Input Impedance..................10 GOhms
•CMRR...................................110 dB
•Input Noise...........................<0.5 uV RMS DC to 200Hz,<1.5uV RMS
•Bandwidth...........................DC-3500 Hz
•Low Pass Filter (Maximum)..-3 dB at 3500 Hz, single pole
•High Pass Filter (Minimum)...DC or -3 dB at .05 Hz, single pole
•Full Scale Input Range (DC Mode).....+/- 200 mV
•System Gain (DC Mode)......10
•Sensitivity (DC Mode)..........24 nV/bit
•Full Scale Input Range (AC Mode).....+/- 995uV
•System Gain (AC Mode)......2010
•Sensitivity (AC Mode)..........3 nV/bit
•Digital (TTL) Inputs...............8 Bit Stimulus, 8 Bit Response
•High Level Input Range........+/- 5 V
•Impedance Measurement.....1K Ohm to 50 K Ohm
•IMRR....................................127 dB
•Headbox Size (h x w x d)...4.5 x18.7 x 21.8cm, per 64 channels
•Headbox Weight..................1.5 kg
•System Unit Size.................23 x 11.6 x 32.5 cm per 256 channels
•System Unit Weight.............4.3 kg
•Power Unit Size..................23 x 11.6 x 32.5 cm per 256 channels
•Power Unit Weight..............12.5 kg
•Device Certification
•EU Risk Classification 2B
•Type CF
•FDA Class II
•FDA Product Code GWQ, GWP, GWF, GWE, GWJ
•Safety Specifications
•EN 60601-1 Medical Electrical Devices - General Requirements for Safety
•UL2601.1 - Including US National Deviations for IEC601-1
•CSA22.2 - Including Canadian National Deviations for IEC601-1
•EN 60601-1-1 - Collateral Standard - Systems
•EN 60601-1-2 - Collateral Standard - Electromagnetic Compatibility
•EN 60601-1-4 - Collateral Standard - Programmable Systems
•EN 60601-2-26 - Specific requirements for electroencephalographs
 
       
    Configuration:  
       
    Offered in or 64 monoplar channel models. Can be chained together for simultaneous acquisition of 64, 96, 128 or 256 monopolar channels.  
       
    REQUIRED SOFTWARE:  
         
      SCAN/ESI 4.3 (or greater)  
         
  IMPORTANTE:
Os produtos
Neuroscan são destinado exclusivamente para Pesquisa Cientifica e sua importação
poderá ser feita apenas por
cientistas, pesquisadores ou Instituições científicas e tecnológicas.
 
         
 

   Biolink Comércio de Equipamentos Médicos Ltda - 2011